060G1889 - Danfoss AKS32 0-100 PSI Transducer
060G1889
Danfoss AKS 32 0-100 PSI Transducer, 1-6V DC output signal, 9-30V DC supply voltage. 8M Cable.
Use with ECI Systems 1/8" NPT.
AKS 32 is a pressure transmitter that measures a pressure and converts the measured value to a 1-6 V DC output signal.
Product Specifications
TYPE CODE | AKS 32 |
WEIGHT | 0.528 Kg |
- COMMON | BLACK |
+ OUTPUT | White |
+ SUPPLY | Red |
ACCURACY, MAX. ±FS | 0,80 % |
ACCURACY, TYPICAL ±FS | 0,3 % |
ADJ. ZERO POINT/SPAN | No |
AMBIENT TEMP. RANGE | -40 - 85 °C |
AMBIENT TEMP. RANGE | -40 - 185 °F |
APPROVAL | ATEX, C UR, CSA, GOST POCC |
APPROVAL NOTE | ATEX Ex nA IIA T3 Gc |
APPROVAL STD. | 6967179 |
APPROVAL STD. | E227388 |
APPROVAL STD. | E31024 |
CABLE | 315,00 in |
CABLE | 8,00 m |
COMPENSATED TEMP. RANGE | -30 - 40 °C |
COMPENSATED TEMP. RANGE | -22 - 104 °F |
EAN NO. | 5702423205424 |
ELECTR. CONN. COMMENTS | Screened |
ELECTR. CONN. TYPE | CABLE |
ENCLOSURE RATING | IP67 |
FLUSH DIAPHRAGM | No |
INTRINS. SAFE | No |
MEDIUM TEMP. | -40 - 85 °C |
MEDIUM TEMP. | -40 - 185 °F |
NON-LINEARITY BFSL ±FS | 0,20 % |
OUTPUT SIGNAL TYPE | 1 - 6 V |
MAX. OVERLOAD PRESS. | 400 psi |
PRESS. CONN. STD. | ANSI/ASME B1.20.1 |
PRESS. CONN. TYPE | NPT - 1/8-27 Male |
PRESS. RANGE | 0,00 - 6,89 bar |
PRESS. RANGE | 0,00 - 100,00 psi |
PRESS. UNIT REF. | Gauge (relative) |
PROD. GROUP | Sensors |
PROD. NAME | Pressure transmitter |
PULSE SNUBBER | No |
MAX. RESPONSE TIME | 4 ms |
SPEC. KEY | AKS 32-5834-B1AC02-0 |
SUPPLY VOLT. DC | 9,00 - 30,00 V |